VIO1008_Stage_Element_2400x1350_GREY.jpg

VIO1008

Voltage Measurement Card

The VIO1008 is a voltage measurement card for the VIO System with 8 differential inputs. 

It delivers the present voltage and a mean voltage value averaged over a definable time (integration time).

Detail View

Detail View

Technical Data

VIO1008
Input Voltage
  • ±5 V
  • ±20 V
  • ±60 V
Signal TypeDifferential
Sampling Rate200 kS/s
Measurement Data Rate (towards CANoe)100 μs
A/D Converter (per Channel)16 Bit / 200 kS/s
Accuracy
  • ±5 V: ±20 mV
  • ±20 V: ±80 mV
  • ±60 V: ±240 mV
Input Impedance> 1 MΩ
Input Capacitance< 15 pF
Galvanic IsolationNo
Measurement CategoryNot RATED (O) according to IEC 61010-2-030
respectively CAT I acc. UL 61010-1
Overvoltage Protection±100 V vs. AGND/DGND
Cut-off Frequency25 kHz
Temperature Range-25 °C to +55 °C
Power Consumption1.6 W

Schematic