The FlexRay Network Interface VN7610 is designed for development, simulation, and testing of FlexRay networks.
The USB connection makes it universally applicable such as in laboratory environments or during test drives, while its highly compact design makes it ideal for mobile applications. In addition, the interface provides access to CAN and CAN FD bus systems.
Highlights
- Simulate large networks efficiently: A 2 MB transmit
sendmemory allows parallel configuration of more than 1000 FlexRay messages. - Autonomous FlexRay cluster startup: Enables a cold start of the FlexRay cluster without requiring an additional network node.
- Analyze startup behavior: Monitoring unit supports analysis of FlexRay network startup.
- FlexRay and CAN FD access: One FlexRay channel (A and B) with access to CAN FD bus systems.
- Minimal footprint: Very compact design for mobile and space‑constrained use cases.
Main Application Areas
Analysis of FlexRay networks and ECUs
VN7610 enables flexible analysis of FlexRay networks and ECUs.
Precise timing analysis
VN7610 supports precise timing analysis of communication data in FlexRay networks.
ECU and gateway testing
VN7610 is suitable for analysis and testing of ECUs and gateway applications.
Custom applications
Custom applications can be created using FlexRay‑specific libraries with VN7610.
Functions
FlexRay
- Dynamic reconfiguration of the CC buffers.
- Transmission and reception of data and null frames.
- Detection of invalid frames.
- Cycle multiplexing and in-cycle response.
- Hardware-based incrementing of a payload area.
- PDU support and FlexRay gateway functionality (channel A).
- Startup and asynchronous monitoring to detect FlexRay frames and symbols before the communication controller synchronizes to the bus.
General
- Synchronization with multiple devices and other bus systems such as CAN FD and LIN.
- Support of CAN FD up to 8 Mbit.
- Fast CAN flashing through hardware-based flash sequence support.
- CAPL-on-Board support for CAN and FlexRay
Technical Data
| VN7610 | |
| Channels | 1 x FlexRay , 1 x CAN(FD) |
| Transceiver | FlexRay: TJA1082 / CAN(FD): TJA1051 |
| FR Comm. Controller Analysis Startup | Bosch E-Ray (FPGA) Bosch E-Ray (FPGA) |
| Send memory | 2 MB |
| FlexRay Cluster (A+B) | 1 |
| PC interface | USB 2.0 |
| Connectors | 1 x D-SUB9 (1) |
| External power supply | via USB |
| Power consumption | 2 W |
| Operating systems | Windows 10 (64 bit) / Windows 11 (64 bit) |
| Temperature range, operating: storage: | -40 °C ... +50 °C -40 °C ... +85 °C |
| Dimensions (LxWxD) | 42 mm x 20 mm x 65 mm |
(1) Cable with D-SUB9 dual channel assignment to two separate D-SUB9 connectors with single channel assignment available as accessory.