Power Supply Module
The VT7001A module can be used to control up to 2 power supply inputs of an ECU (e.g. terminals 15 and 30). As an alternative, 2 ECUs may be supplied separately, e.g. for testing differences in voltage supplies.
Characteristics
Module Features
- 2 external power supplies can be connected
- Internal power supply generates voltage for the ECU from the VT System power supply
- 2 external and 1 internal power supplies may be connected to the 2 outputs to the ECU in various combinations
- Ground lines of outputs can be interrupted (line break of terminal 31)
- Relays for producing short circuits between the output lines
- Measurement of output currents over a very wide range
- Measurement of input and output voltages
- Control of two external power supplies via control voltage or via electrically decoupled serial interfaces
- Generation of arbitrary control voltage curve
- Serial interface for driving an external display
- Hardware synchronization with Vector network interfaces
- The module supplies ground and battery voltage to the bus bars at additional pins
Technical Data
| VT7001A | ||
| Input voltage | -40 … +40 V | |
| Current carrying capacity (at 0 … 35°C) | ||
| One channel | Max. 70 A | |
| Both channels in sum | Max. 100 A | |
| Internal power supply | ||
| Output voltage | 3 … 30 V | |
| Accuracy (at 25°C, 0.5 A) | ± (2.0 % + 100 mV) | |
| Output current | ||
| – at output voltage ≤ 30 V | Max. 0.5 A | |
| – at output voltage ≤ 15 V | Max. 2 A | |
| Current measurement | ||
| Measurement ranges | 7 (100 µA … 100 A) | |
| Accuracy (at 25 °C) | ± (0.5 % + offset) (offset is dependent on measurement range) | |
| A/D converter (per channel, internal) | 16 Bit / 250 kSamples/s | |
| Voltage measurement | ||
| Accuracy (at 25 °C) | ± (1.0 % + 120 mV) | |
| A/D converter (per channel, internal) | 16 Bit/250 kSamples/s | |
| Control voltage of external power supply | ||
| Control voltage for voltage/current | -10 … +10 V | |
| Accuracy (at 25 °C) | ± (0.05 % + 40 mV) | |
| Output current | Max. 30 mA | |
| Basic Data | ||
| Supply voltage (via backplane) | 12 V ±10 % | |
| Power consumption (all relays off) | Typ. 7 W | |
| Power consumption (8 relays active, output 12 V/1 A via internal power supply | Typ. 33 W | |
| Temperature range | 0 … 55 °C | |
| Dimensions (L x W x H) | 300 x 173 x 36 mm | |
| Weight | Approx. 1,240 g | |
| Maintenance | ||
| Calibration recommended | every 12 months | |
| Accredited (pre/re) calibration according to | ISO/IEC 17025:2017 | |