The VIO1208A.MT is designed for measuring analog sensors and transducers.
The card provides eight galvanically isolated channels with individual sensor excitation that can be configured independently.
It supports sensors and transducers with voltage output or current loop interfaces.
Detail View


Technical Data
| VIO1208A.MT | |
| Input Ranges (Voltage Mode) |
|
| Input Range (Current Mode) | 4 mA … 20 mA, internally or externally powered |
| Sensor Excitation |
|
| Measurement Data Rate (towards Tool) | 100 µs …1 s, adjustable per channel |
| A/D Converter (per Channel) | Delta Sigma, 18biteff Built-in 3rd order sinc filter |
| Accuracy (at 23°C ambient temperature) |
|
| Input Impedance (Voltage Mode) | 5 MΩ II 200 pF typ. |
| Galvanic Isolation |
|
| Overvoltage Protection |
|
| Excitation Protection | Overload and short-circuit |
| Temperature Range | -25 °C ... +55 °C |
| Connector | 5 pin push-in-plug type PTSM 0.5/5-P-2.5 |
| Power Consumption | 6.0 W typ. / 12.0 W max. (with full Sensor Excitation) |
Schematic